Errata for "Bartendr: A Practical Approach to Energy-aware Cellular Data Scheduling" Last updated: October 6, 2010 Section 2 paragraph 4: Incorrect: .01 Ohm precision shunt resistor Correct: 0.1 Ohm precision shunt resistor Figure 5 caption: Incorrect: 62 SSL email syncs Correct: 60 SSL email syncs Figure 2: CDFs computed incorrectly but revised CDFs do not alter the conclusions